Exterior Linear Pro Cove CTC

Outdoor Linear Cove Fixture with Colour Temperature Control


Martin Exterior Linear Pro Cove CTC lights are flexible, compact, LED-based architectural fixtures. Delivering uniform light distribution at a 100 degree beam angle, they are ideal for striking indirect lighting of ceilings, walls and other surfaces in stadiums and arenas, cruise ships, theme parks, hotels, casinos, bridges, tunnels or other permanent indoor or outdoor locations.

Featuring highly efficient colour temperature control (2700K, 4000K, 6500K), a high colour rendering index (CRI) and 12 LEDs/ft, Cove CTC models deliver robust output of 800 lm/ft, perfect for illuminating high walls and surfaces while maintaining lumen intensity. Packed with intelligent features, Cove CTC lights include multiple power modes, Remote Device Management (RDM), simple-to-adjust total lumen output for low power requirements, DMX-controllability, and easy installation via the integrated universal power supply.

With a high focus on sustainability, these fixtures can be daisy-chained using a combined power and data connector, enabling long fixture runs for simpler infrastructures. Simple beam angle changeability makes late design changes and on-site adjustments easy and a smart mounting plate design allows for a range of standard or custom bracket solutions.

The slim design makes these lights easier to integrate into architectural elements with less structural requirements. All models are available in either 1ft or 4ft linear lengths and are shipped in FSC certified packaging.

  • Warm, neutral and cold white LED colour temperature control (2700K, 4000K, 6500K) (12 LEDs/ft)
  • 100° beam angle for indirect lighting applications
  • Selectable segment modes (1, 4 or 8 segments)
  • Selectable power consumption (12W/10W/5W) per foot
  • 5W/ft power mode meets ASHRAE standards for linear facade lighting
  • Integrated multi-range power supply unit (PSU) 100-277V for long fixture runs
  • Hybrid power and data connector for easy daisy-chained configurations
  • DMX and RDM control
  • Integrated magnetic switch for local diagnostics
  • Rugged IP66 housing designed for permanent outdoor installations
  • Low weight 0.8 kg/ft (1.9 lbs/ft)
  • Compact design - 40mm (1.57 inch) width

PHYSICAL

Width: 40 mm (1.57 inch.)

Height: 68 mm (2.67 inch)

Length - 1 ft Version: 312mm (1.02 ft)

Length - 4 ft Version: 1227mm (4.02 ft)

Weight - 1 ft Version: 0.85 kg (1.9 lbs)

Weight - 4 ft Version: 2.8 kg (6.2 lbs)


DYNAMIC EFFECTS

Colour temperature control: 2700 K – 6500 K

Intensity: 0 - 100%

Segment Control: 0.5ft, 1 ft or full 4 ft fixture control


CONTROL AND PROGRAMMING

Control systems: DMX, RDM

Control resolution: 8-bit DMX individual color control

User interface: Magnetic button to call up fixture status and test fixture

Stand-alone control: Up to 20 scenes with individual fade/hold times

DMX compliance: USITT DMX512/1990

RDM compliance: ANSI/ESTA E1.20

Dimmer Resolution: 16-bit DMX control of intensity

DMX channels 4ft: 3/3/12/24 (standard/1 seg/4 seg/8 seg)

DMX channels 1ft: 3/6/3 (standard/1 seg/2 seg)

OPTICS

Light source: White colour (2700k, 4000K, 6500K) LED (12 LEDs per foot)

Minimum LED lifetime: 50 000 hours (to >70% luminous output)*

Beam angle: 100°

Binning: Tight color and flux binning

Calibration: Full Gamut Colour Calibration (1 step MacAdam ellipse)

*Figure obtained under manufacturer's test conditions


PHOTOMETRIC DATA

CRI (Color Rendering Index) : >70 (higher CRI available on request)

CCT: 2700K - 6500K

Luminous output:

1 ft at 12W.                 4 ft at 48W

2700K:520 lumens     2100 lumens

4000K:580 lumens     2360 lumens

6500K:560 lumens     2250 lumens

* All Photometric Data measured in steady state (30 minutes warm-up time) at 25°C ambient.



CONNECTIONS
Power/data in/thru: 8-pin custom connectors
Surge Protection: 4 KV
Maximum connected 4 ft fixtures *: 42 pcs (52 m /169 ft) @ 230-277 V
Maximum total string length (cable + fixtures)*: 150 m / 328 ft
* Refer to system diagram for details on fixture run limitations.

ELECTRICAL
AC power: 100-277 V AC nominal, 50/60 Hz
Power supply unit: Auto-ranging electronic switch mode
Typical half-cycle RMS inrush current at 230 V, 50 Hz: 0.35 A
Typical earth-leakage current 1 ft: 0.15 mA
Typical earth-leakage current 4 ft: 0.21 mA
Power Factor 12 W / 10 W mode: 0.95 @ 100 V / 120 V / 208 V / 230 V / 240 V , 0.90 @ 277 V
Power Factor 5 W mode: 0.90 @ 100 V / 120 V / 208 V / 230 V / 240 V , 0.70 @ 277 V

Power Consumption 1 ft
Maximum: 12 W / 10 W / 5 W *
Idle: 1.54 W *

Power Consumption 4 ft
Maximum: 48 W / 40 W / 20 W *
Idle: 2.30 W *

* Measurements made at nominal voltage. Allow for a deviation of +/- 10%.
Idle: steady state, all LEDs at zero intensity.
Power Consumption: Depending on power setting mode.

THERMAL
Cooling: Convection
Total heat dissipation (calculated, +/- 10%): 41 BTU/hr. per foot
Maximum ambient temperature: 45° C (113° F)*
Minimum ambient temperature: -30° C (-22° F)
*Above this temperature, the fixture regulates output to protect from overheating

SKU Manufacturer’s SKU Image Name Colour/description
MAR1930 MAR-90570007 MARTIN EXTERIOR Linear Pro-Cove, CTC, 1ft MARTIN EXTERIOR Linear Pro-Cove, CTC, 1ft Cove CTC - 1ft
MAR1931 MAR-90570009 MARTIN EXTERIOR Linear Pro-Cove, CTC, 4ft MARTIN EXTERIOR Linear Pro-Cove, CTC, 4ft Cove CTC - 4ft