Bquad

SRP from £156.52 + VAT

The B-quad serves as the heart in any B-series power distribution solution together with the B12 and the B24 units. It provides power and metering for up to four separate B-series units but can of course be used in any situation where a reliable and flexible 3-phase power distribution unit is needed. 

The B-quad is a fully customizable, four output, 3-phase power distribution that’s fitted with the same high grade hydraulic-magnetic circuit breakers as the acclaimed C-series, providing you with market leading thermal stability, precise specifications, and superior handling of intermittent peak currents.

The B-quad can be customized to fit your specific needs on order, enabling you to choose between 125A or 63A power-inlet connections. An optional Diris A10 multimeter can be fitted enabling reliable measurements of total current consumption, voltages and more. Each of the four outputs can be fitted with 16, 32 or 63A circuit breakers and corresponding CEE output connector. Furthermore, each separate output can have an individual programmable residual current measurement meter fitted, enabling you to fine tune the outputs residual current protection to fit your needs in any given situation without tampering with the safety of people and equipment.

The B-quad gives you the ability to easily adapt to the ever changing challenges of the entertainment industry market in a compact, flexible and reliable unit that will keep you and your staff safe at any time.


Hydraulic-magnetic MCB

The hydraulic-magnetic 4-pole circuit breaker used in the B-quad handles inrush currents and complex loads better than the thermal-magnetic breakers commonly used in other power distribution systems. Perfectly stable over a wide range of operating temperatures and industrial grade protection against dust and humidity makes for a big advantage. Zero reset-time and no “nuisance tripping” are just some of the features that will keep your show going.

Adjustable RCDs

Each of the four B-qaud outputs can be fitted with an optional programmable Residual Current Meter, to keep you and your staff safe at all times. The RCM enables you to optimize the earth leakage protection for motor-controllers, inverters, and other power distribution units further along the line. Parameters can be set individually for each output with a simple interface.

Input metering

The B-quad can be fitted with an optional Diris A10 multifunctional input meter. This enables you to measure incoming voltages, current consumption per phase, neutral current and much more.

Harting GND connector

The B-quad incorporates the now widely adopted HAN-GND connector for grounding and potential equalization in the event and show industry. B-quad makes it easy and quick to connect and equalize the grounds in your setup.

Power input125A or 63A CEE, 5-wire (TN-S) 230/400V
Main breakerDisconnector, 4-pole 125A
Main input metering (optional)All incoming voltages, all currents (including neutral current), power factor, frequency
No of main channels4
Channel capacity and protection16A-63A, 4-pole breaker, (optional) programmable RCM (10mA-30A) (0.0-99.9s)
Main output connections16A, 32A or 63A CEE, 5-wire (TN-S) 230/400V
Dimensions & weight483(19″) x 311(7U) x 373mm, 18kg
Certifications, standardsEN 61439-1, EN 62368-1:2014, EN 61000-6-1:2007,EN 55015:2006+A2:2009, BS7671, BS7909
SKU Manufacturer’s SKU Image Name Colour/description
STG0029 BQ-BU-125 BQ-BU-125 BQ-BU-125 B-Quad base unit, CEE 125A input, main switch, system meter
STG0030 BQ-BU-63 BQ-BU-63 BQ-BU-63 B-Quad base unit, CEE 63A input, main switch, system meter
STG0031 BQ-BO32 BQ-BO32 BQ-BO32 CEE 32A outlet without RCM
STG0032 BQ-BO32-RCM BQ-BO32-RCM BQ-BO32-RCM CEE 32A outlet with RCM
STG0033 BQ-BO63 BQ-BO63 BQ-BO63 CEE 63A outlet without RCM
STG0034 BQ-BO63-RCM BQ-BO63-RCM BQ-BO63-RCM CEE 63A outlet with RCM